(a)If you manufacture multi-component kits as defined in § 59.503, then the Kit PWR must not exceed the Total Reactivity Limit.
(b)You must calculate the Kit PWR and the Total Reactivity Limit as follows:
(1)KIT PWR = (PWR(1) × W1) + (PWR(2) × W2) + . ... + (PWR(n) × Wn)
(2)Total Reactivity Limit = (RL1 × W1) + (RL2 × W2) + ... + (RLn × Wn).
(3)Kit PWR ≤Total Reactivity Limit. Where: W = the weight of the product contents (excluding container). RL = the PWR Limit specified in Table 1 of this subpart. Subscript 1 denotes the first component product in the kit. Subscript 2 denotes the second component product in the kit. Subscript n denotes any additional component product.