§ 18.35. Portable (trailing) cables and cords.

433 words·~2 min read·/us/cfr/t30/s§ 18.35·

A research copy — for the controlling text, always check the official state or federal source. Not legal advice.

(a)Portable cables and cords used to conduct electrical energy to face equipment shall conform to the following:
(1)Have each conductor of a current-carrying capacity consistent with the Insulated Power Cable Engineers Association (IPCEA) standards. (See Tables 1 and 2 in Appendix I.)
(2)Have current-carrying conductors not smaller than No. 14 (AWG). Cords with sizes 14 to 10
(AWG)conductors shall be constructed with heavy jackets, the diameters of which are given in Table 6 in Appendix I.
(3)Be accepted as flame resistant under this part or approved under subpart K of part 7 of this chapter.
(4)Have short-circuit protection at the outby (circuit-connecting) end of ungrounded conductors. (See Table 8 in Appendix I.) The fuse rating or trip setting shall be included in the assembler's specifications.
(5)Ordinarily the length of a portable (trailing) cable shall not exceed 500 feet. Where the method of mining requires the length of a portable (trailing) cable to be more than 500 feet, such length of cable shall be permitted only under the following prescribed conditions:
(i)The lengths of portable (trailing) cables shall not exceed those specified in Table 9, Appendix I, titled "Specifications for Portable Cables Longer Than 500 Feet."
(ii)Short-circuit protection shall be provided by a protective device with an instantaneous trip setting as near as practicable to the maximum starting-current-inrush value, but the setting shall not exceed the trip value specified in MSHA approval for the equipment for which the portable (trailing) cable furnishes electric power.
(6)Have nominal outside dimensions consistent with IPCEA standards. (See Tables 4, 5, 6, and 7 in Appendix I.)
(7)Have conductors of No. 4
(AWG)minimum for direct-current mobile haulage units or No. 6
(AWG)minimum for alternating-current mobile haulage units.
(8)Have not more than five well-made temporary splices in a single length of portable cable.
(b)Sectionalized portable cables will be acceptable provided the connectors used inby the last open crosscut in a gassy mine meet the requirements of § 18.41.
(c)A portable cable having conductors smaller than No. 6 (AWG), when used with a trolley tap and a rail clamp, shall have well insulated single conductors not smaller than No. 6
(AWG)spliced to the outby end of each conductor. All splices shall be made in a workmanlike manner to insure good electrical conductivity, insulation, and mechanical strength.
(d)Suitable provisions shall be made to facilitate disconnection of portable cable quickly and conveniently for replacement. \[33 FR 4660, Mar. 19, 1968; 33 FR 6343, Apr. 26, 1968, as amended at 57 FR 61223, Dec. 23, 1992\]
Connections93 cite this
Cited by 93 sections · top 59
register
Citation graph
cites case law
§ 18.35
Portable (trailing) cables and cords.
Fed. Reg.×93
Cites 0Cited by 93 across 1 source
★   the supreme law of the land   ★
Don't Tread on Me
E Pluribus Unum — out of many, one

"If you don't know your rights, you don't have any."

Marginalia · a citizen's law index
A research desk, not legal advice. Always read the cited source before relying on a summary.
Questions or an issue? support@self-law.org
disclaimerMarginalia is a research index, not a law firm. Nothing on this site is legal, tax, or financial advice and no attorney–client relationship is formed by using it. Statutes, regulations, and case law change; summaries, search results, AI output, and member posts may be incomplete, out of date, or wrong. Any interpretation drawn from material on this site should be validated by a licensed attorney in your jurisdiction before you act on it.