15A-5-205. Amendments and additions to IFC related to means of egress and special processes and uses.
(1)IFC, Chapter 10, Section 1010.2.14, Controlled egress doors in Groups I-1 and I-2, after existing Item 8 add Item 9 as follows: "9. The secure area or unit with special egress locks shall be located at the level of exit discharge in Type V construction."
(2)IFC, Chapter 10, Section 1010.2.13.1, Delayed egress locking system, Item 9 is added after the existing Item 8 as follows: "9. The secure area or unit with delayed egress locks shall be located at the level of exit discharge in Type V construction."
(3)IFC, Chapter 10, Section [BE] 1011.5.2, Riser height and tread depth, Exception 3 is deleted and replaced with the following: "3. In Group R-3 occupancies, within dwelling units in Group R-2 occupancies, and in Group U occupancies that are accessory to a Group R-3 occupancy, or accessory to individual dwelling units in Group R-2 occupancies, the maximum riser height shall be 8 inches (203 mm) and the minimum tread depth shall be 9 inches (229 mm). The minimum winder tread depth at the walk line shall be 10 inches (254 mm), and the minimum winder tread depth shall be 6 inches (152 mm). A nosing not less than 0.75 inch (19.1 mm) but not more than 1.25 inches (32 mm) shall be provided on stairways with solid risers where the tread depth is less than 10 inches (254 mm)."
(4)IFC, Chapter 10, Section [BE] 1011.11, Handrails, is amended to add the following exception: " 6. In occupancies in Group R-3, as applicable in Section 1014 and in occupancies in Group U, which are accessory to an occupancy in Group R-3, as applicable in Section 1014, handrails shall be provided on at least one side of stairways consisting of four or more risers."
(5)IFC, Chapter 10, Section 1032.2.1, Security devices and egress locks, is amended to add the following: On line three, after the word "fire", add the words "and building."
Amended by Chapter 95 , 2023 General Session
★   the supreme law of the land   ★
Don't Tread on Me
E Pluribus Unum — out of many, one

"If you don't know your rights, you don't have any."

Marginalia · a citizen's law index
A research desk, not legal advice. Always read the cited source before relying on a summary.
Questions or an issue? support@self-law.org
disclaimerMarginalia is a research index, not a law firm. Nothing on this site is legal, tax, or financial advice and no attorney–client relationship is formed by using it. Statutes, regulations, and case law change; summaries, search results, AI output, and member posts may be incomplete, out of date, or wrong. Any interpretation drawn from material on this site should be validated by a licensed attorney in your jurisdiction before you act on it.