§ 62.14650. How do I conduct the initial and annual performance test?

317 words·~1 min read·/us/cfr/t40/s§ 62.14650·

A research copy — for the controlling text, always check the official state or federal source. Not legal advice.

(a)All performance tests must consist of a minimum of three test runs conducted under conditions representative of normal operations.
(b)You must document that the waste burned during the performance test is representative of the waste burned under normal operating conditions by maintaining a log of the quantity of waste burned (as required in § 62.14700(b)(1)) and the types of waste burned during the performance test.
(c)All performance tests must be conducted using the minimum run duration specified in Table 1 of this subpart.
(d)Method 1 of 40 CFR part 60, appendix A must be used to select the sampling location and number of traverse points.
(e)Method 3A or 3B of 40 CFR part 60, appendix A must be used for gas composition analysis, including measurement of oxygen concentration. Method 3A or 3B of 40 CFR part 60, appendix A must be used simultaneously with each method.
(f)All pollutant concentrations, except for opacity, must be adjusted to 7 percent oxygen using Equation 1 of this section: Cadj = C meas (20.9−7)/(20.9−%O2) (Eq. 1) Where: Cadj = pollutant concentration adjusted to 7 percent oxygen; Cmeas = pollutant concentration measured on a dry basis; (20.9−7) = 20.9 percent oxygen−7 percent oxygen (defined oxygen correction basis); 20.9 = oxygen concentration in air, percent; and %O2 = oxygen concentration measured on a dry basis, percent.
(g)You must determine dioxins/furans toxic equivalency by following the procedures in paragraphs (g)(1) through
(3)of this section.
(1)Measure the concentration of each dioxin/furan tetra- through octa-congener emitted using EPA Method 23.
(2)For each dioxin/furan congener measured in accordance with paragraph (g)(1) of this section, multiply the congener concentration by its corresponding toxic equivalency factor specified in Table 3 of this subpart.
(3)Sum the products calculated in accordance with paragraph (g)(2) of this section to obtain the total concentration of dioxins/furans emitted in terms of toxic equivalency.
Connections5 cite this
Cited by 5 sections · top 2
1 reference not yet in our index
  • 40 CFR 60
Citation graph
cites case law
§ 62.14650
How do I conduct the initial and annual performance test?
Fed. Reg.×5
Cite40 CFR 60
Cites 1Cited by 5 across 1 source
★   the supreme law of the land   ★
Don't Tread on Me
E Pluribus Unum — out of many, one

"If you don't know your rights, you don't have any."

Marginalia · a citizen's law index
A research desk, not legal advice. Always read the cited source before relying on a summary.
Questions or an issue? support@self-law.org
disclaimerMarginalia is a research index, not a law firm. Nothing on this site is legal, tax, or financial advice and no attorney–client relationship is formed by using it. Statutes, regulations, and case law change; summaries, search results, AI output, and member posts may be incomplete, out of date, or wrong. Any interpretation drawn from material on this site should be validated by a licensed attorney in your jurisdiction before you act on it.