§ 61.242-5. Standards: Sampling connecting systems.
253 words·~1 min read·
/us/cfr/t40/s§ 61.242-5·A research copy — for the controlling text, always check the official state or federal source. Not legal advice.
(a)Each sampling connection system shall be equipped with a closed-purge, closed-loop, or closed vent system, except as provided in § 61.242-1(c). Gases displaced during filling of the sample container are not required to be collected or captured.
(b)Each closed-purge, closed-loop, or closed vent system as required in paragraph
(a)of this section shall comply with the requirements specified in paragraphs (b)(1) through
(4)of this section:
(1)Return the purged process fluid directly to the process line; or
(2)Collect and recycle the purged process fluid; or
(3)Be designed and operated to capture and transport all the purged process fluid to a control device that complies with the requirements of § 61.242-11; or
(4)Collect, store, and transport the purged process fluid to any of the following systems or facilities:
(i)A waste management unit as defined in 40 CFR 63.111 if the waste management unit is subject to and operated in compliance with the provisions of 40 CFR part 63, subpart G, applicable to Group 1 wastewater streams; or
(ii)A treatment, storage, or disposal facility subject to regulation under 40 CFR part 262, 264, 265, or 266; or
(iii)A facility permitted, licensed, or registered by a State to manage municipal or industrial solid waste, if the process fluids are not hazardous waste as defined in 40 CFR part 261.
(c)In-situ sampling systems and sampling systems without purges are exempt from the requirements of paragraphs
(a)and
(b)of this section. [65 FR 78281, Dec. 14, 2000]
Connections1 cite this · traces to 1
Cited by 1 section
Traces to 1 document
3 references not yet in our index
- 40 CFR 63
- 40 CFR 262
- 40 CFR 261
Citation graph
cites case law
§ 61.242-5
Standards: Sampling connecting systems.
C.F.R.×1
Cite40 CFR 63
Cite40 CFR 262
Cite40 CFR 261
Cites 4Cited by 1 across 1 source