§ 60.4335. How do I demonstrate compliance for NOX if I use water or steam injection?

296 words·~1 min read·/us/cfr/t40/s§ 60.4335·

A research copy — for the controlling text, always check the official state or federal source. Not legal advice.

(a)If you are using water or steam injection to control NOX emissions, you must install, calibrate, maintain and operate a continuous monitoring system to monitor and record the fuel consumption and the ratio of water or steam to fuel being fired in the turbine when burning a fuel that requires water or steam injection for compliance.
(b)Alternatively, you may use continuous emission monitoring, as follows:
(1)Install, certify, maintain, and operate a continuous emission monitoring system
(CEMS)consisting of a NOX monitor and a diluent gas (oxygen
(O2)or carbon dioxide (CO2)) monitor, to determine the hourly NOX emission rate in parts per million
(ppm)or pounds per million British thermal units (lb/MMBtu); and
(2)For units complying with the output-based standard, install, calibrate, maintain, and operate a fuel flow meter (or flow meters) to continuously measure the heat input to the affected unit; and
(3)For units complying with the output-based standard, install, calibrate, maintain, and operate a watt meter (or meters) to continuously measure the gross electrical output of the unit in megawatt-hours; and
(4)For combined heat and power units complying with the output-based standard, install, calibrate, maintain, and operate meters for useful recovered energy flow rate, temperature, and pressure, to continuously measure the total thermal energy output in British thermal units per hour (Btu/h).
(5)For affected units that are also regulated under part 75 of this chapter, the NOX emission rate may be monitored using a NOX diluent CEMS that is installed and certified in accordance with appendix A to part 75 and the QA program in appendix E to part 75, or the low mass emissions methodology in § 75.19 of this chapter. [71 FR 38497, July 6, 2006, as amended at 91 FR 1980, Jan. 15, 2026]
Connections1 cite this
Cited by 1 section
Citation graph
cites case law
§ 60.4335
How do I demonstrate compliance for NOX if I use water or steam injection?
Fed. Reg.×1
Cites 0Cited by 1 across 1 source
★   the supreme law of the land   ★
Don't Tread on Me
E Pluribus Unum — out of many, one

"If you don't know your rights, you don't have any."

Marginalia · a citizen's law index
A research desk, not legal advice. Always read the cited source before relying on a summary.
Questions or an issue? support@self-law.org
disclaimerMarginalia is a research index, not a law firm. Nothing on this site is legal, tax, or financial advice and no attorney–client relationship is formed by using it. Statutes, regulations, and case law change; summaries, search results, AI output, and member posts may be incomplete, out of date, or wrong. Any interpretation drawn from material on this site should be validated by a licensed attorney in your jurisdiction before you act on it.