§ 60.372. Standards for lead.
390 words·~2 min read·
/us/cfr/t40/s§ 60.372·A research copy — for the controlling text, always check the official state or federal source. Not legal advice.
(a)On and after the date on which the performance test required to be conducted by § 60.8 is completed, no owner or operator subject to the provisions of this subpart shall cause to be discharged into the atmosphere:
(1)From any grid casting facility any gases that contain lead in excess of 0.40 milligram of lead per dry standard cubic meter of exhaust (0.000175 gr/dscf).
(2)From any paste mixing facility any gases that contain in excess of 1.00 milligram of lead per dry standard cubic meter of exhaust (0.000437 gr/dscf).
(3)From any three-process operation facility any gases that contain in excess of 1.00 milligram of lead per dry standard cubic meter of exhaust (0.000437 gr/dscf).
(4)From any lead oxide manufacturing facility any gases that contain in excess of 5.0 milligrams of lead per kilogram of lead feed (0.010 lb/ton).
(5)From any lead reclamation facility any gases that contain in excess of 4.50 milligrams of lead per dry standard cubic meter of exhaust (0.00197 gr/dscf).
(6)From any other lead-emitting operation any gases that contain in excess of 1.00 milligram of lead per dry standard cubic meter of exhaust (0.000437 gr/dscf).
(7)From any affected facility other than a lead reclamation facility any gases with greater than 0 percent opacity (measured according to Method 9 and rounded to the nearest whole percentage).
(8)From any lead reclamation facility any gases with greater than 5 percent opacity (measured according to Method 9 and rounded to the nearest whole percentage).
(b)When two or more facilities at the same plant (except the lead oxide manufacturing facility) are ducted to a common control device, an equivalent standard for the total exhaust from the commonly controlled facilities shall be determined as follows: Where: Se = is the equivalent standard for the total exhaust stream. Sa = is the actual standard for each exhaust stream ducted to the control device. N = is the total number of exhaust streams ducted to the control device. Qsda = is the dry standard volumetric flow rate of the effluent gas stream from each facility ducted to the control device. QsdT = is the total dry standard volumetric flow rate of all effluent gas streams ducted to the control device. [47 FR 16573, Apr. 16, 1982, as amended at 65 FR 61760, Oct. 17, 2000]