(a)The owner or operator shall conduct performance tests required in § 60.8 only when the following quantities of product are being cured or stored in the facility.
(1)Total granular triple superphosphate is at least 10 percent of the building capacity, and
(2)Fresh granular triple superphosphate is at least 6 percent of the total amount of triple superphosphate, or
(3)If the provision in paragraph (a)(2) of this section exceeds production capabilities for fresh granular triple superphosphate, fresh granular triple superphosphate is equal to at least 5 days maximum production.
(b)In conducting the performance tests required in § 60.8, the owner or operator shall use as reference methods and procedures the test methods in appendix A of this part or other methods and procedures as specified in this section, except as provided in § 60.8(b).
(c)The owner or operator shall determine compliance with the total fluorides standard in § 60.242 as follows:
(1)The emission rate
(E)of total fluorides shall be computed for each run using the following equation: where: E = emission rate of total fluorides, g/hr/Mg (lb/hr/ton) of equivalent P2O5 stored. Csi = concentration of total fluorides from emission point “i,” mg/dscm (gr/dscf). Qsdi = volumetric flow rate of effluent gas from emission point “i,” dscm/hr (dscf/hr). N = number of emission points in the affected facility. P = equivalent P2O5 stored, metric tons (tons). K = conversion factor, 1000 mg/g (7,000 gr/lb).
(2)Method 13A or 13B shall be used to determine the total fluorides concentration
(Csi)and volumetric flow rate
(Qsdi)of the effluent gas from each of the emission points. The sampling time and sample volume for each run shall be at least 60 minutes and 0.85 dscm (30 dscf).
(3)The equivalent P2O5 feed rate
(P)shall be computed for each run using the following equation: P = Mp Rp where: Mp = amount of product in storage, Mg (ton). Rp = P2O5 content of product in storage, weight fraction.
(i)The accountability system of § 60.243(a) shall be used to determine the amount of product
(Mp)in storage.
(ii)The Association of Official Analytical Chemists
(AOAC)Method 9 (incorporated by reference—see § 60.17) shall be used to determine the P2O5 content
(Rp)of the product in storage. [54 FR 6671, Feb. 14, 1989, as amended at 62 FR 18280, Apr. 15, 1997; 65 FR 61757, Oct. 17, 2000]
★   the supreme law of the land   ★
Don't Tread on Me
E Pluribus Unum — out of many, one

"If you don't know your rights, you don't have any."

Marginalia · a citizen's law index
A research desk, not legal advice. Always read the cited source before relying on a summary.
Questions or an issue? support@self-law.org
disclaimerMarginalia is a research index, not a law firm. Nothing on this site is legal, tax, or financial advice and no attorney–client relationship is formed by using it. Statutes, regulations, and case law change; summaries, search results, AI output, and member posts may be incomplete, out of date, or wrong. Any interpretation drawn from material on this site should be validated by a licensed attorney in your jurisdiction before you act on it.