§ 57.6407. Circuit testing.

134 words·~1 min read·/us/cfr/t30/s§ 57.6407·

A research copy — for the controlling text, always check the official state or federal source. Not legal advice.

A blasting galvanometer or other instrument designed for testing blasting circuits shall be used to test the following:
(a)In surface operations---
(1)Continuity of each electric detonator in the blasthole prior to stemming and connection to the blasting line;
(2)Resistance of individual series or the resistance of multiple balanced series to be connected in parallel prior to their connection to the blasting line;
(3)Continuity of blasting lines prior to the connection of electric or electronic detonator series; and
(4)Total blasting circuit resistance prior to connection to the power source.
(b)In underground operations---
(1)Continuity of each electric detonator series; and
(2)Continuity of blasting lines prior to the connection of electric or electronic detonators. \[61 FR 36801, July 12, 1996, as amended at 85 FR 2027, Jan. 14, 2020\]
★   the supreme law of the land   ★
Don't Tread on Me
E Pluribus Unum — out of many, one

"If you don't know your rights, you don't have any."

Marginalia · a citizen's law index
A research desk, not legal advice. Always read the cited source before relying on a summary.
Questions or an issue? support@self-law.org
disclaimerMarginalia is a research index, not a law firm. Nothing on this site is legal, tax, or financial advice and no attorney–client relationship is formed by using it. Statutes, regulations, and case law change; summaries, search results, AI output, and member posts may be incomplete, out of date, or wrong. Any interpretation drawn from material on this site should be validated by a licensed attorney in your jurisdiction before you act on it.