Tap any paragraph to write a margin note. Your notes collect in the Desk below the text and file under cases with @. The side-by-side margin rail opens on a larger screen.

Code · CFR · Title 30 — Mineral Resources · Part 57 · § 57.5066

§ 57.5066. Maintenance standards.

440 words·~2 min read·/us/cfr/t30/s§ 57.5066·

A research copy — for the controlling text, always check the official state or federal source. Not legal advice.

(a)Any diesel powered equipment operated at any time in underground areas must meet the following maintenance standards:
(1)The operator must maintain any approved engine in approved condition;
(2)The operator must maintain the emission related components of any non-approved engine to manufacturer specifications; and
(3)The operator must maintain any emission or particulate control device installed on the equipment in effective operating condition. (b)(1) A mine operator must authorize each miner operating diesel-powered equipment underground to affix a visible and dated tag to the equipment when the miner notes evidence that the equipment may require maintenance in order to comply with the maintenance standards of paragraph
(a)of this section. The term evidence means visible smoke or odor that is unusual for that piece of equipment under normal operating procedures, or obvious or visible defects in the exhaust emissions control system or in the engine affecting emissions.
(2)A mine operator must ensure that any equipment tagged pursuant to this section is promptly examined by a person authorized to maintain diesel equipment, and that the affixed tag not be removed until the examination has been completed. The term promptly means before the end of the next shift during which a qualified mechanic is scheduled to work.
(3)A mine operator must retain a log of any equipment tagged pursuant to this section. The log must include the date the equipment is tagged, the date the equipment is examined, the name of the person examining the equipment, and any action taken as a result of the examination. The operator must retain the information in the log for one year after the date the tagged equipment was examined.
(c)Persons authorized by a mine operator to maintain diesel equipment covered by paragraph
(a)of this section must be qualified, by virtue of training or experience, to ensure that the maintenance standards of paragraph
(a)of this section are observed. An operator must retain appropriate evidence of the competence of any person to perform specific maintenance tasks in compliance with those standards for one year after the date of any maintenance, and upon request must provide the documentation to the authorized representative of the Secretary. \[66 FR 5907, Jan. 19, 2001, as amended at 67 FR 9184, Feb. 27, 2002\] Effective Date Note:At 66 FR 5907, Jan. 19, 2001, § 57.5066 was added, effective July 5, 2001, except for paragraph (b). At 66 FR 35518, July 5, 2001, the effective date of paragraph
(b)was delayed pending disposition of current litigation challenging the rule. At 67 FR 9184, Feb. 27, 2002, paragraphs (b)(1) and (b)(2) were revised, effective Mar. 29, 2002.
Connections8 cite this
Citation graph
cites case law
§ 57.5066
Maintenance standards.
Fed. Reg.×8
Cites 0Cited by 8 across 1 source
★   the supreme law of the land   ★
Don't Tread on Me
E Pluribus Unum — out of many, one

"If you don't know your rights, you don't have any."

Marginalia · a citizen's law index
A research desk, not legal advice. Always read the cited source before relying on a summary.
Questions or an issue? support@self-law.org
disclaimerMarginalia is a research index, not a law firm. Nothing on this site is legal, tax, or financial advice and no attorney–client relationship is formed by using it. Statutes, regulations, and case law change; summaries, search results, AI output, and member posts may be incomplete, out of date, or wrong. Any interpretation drawn from material on this site should be validated by a licensed attorney in your jurisdiction before you act on it.