§ 35.21. Temperature-pressure spray-ignition tests.

414 words·~2 min read·/us/cfr/t30/s§ 35.21·

A research copy — for the controlling text, always check the official state or federal source. Not legal advice.

(a)Purpose. The purpose of this test shall be to determine the flammability of a hydraulic fluid when it is sprayed over three different sources of ignition which are described in paragraph (b)(4) of this section.
(b)Description of apparatus.
(1)A 3-quart pressure vessel, with the necessary connections, valves, and heating elements, shall be used for containing and heating the fluid under the test conditions as specified hereinafter.
(2)An atomizing round-spray nozzle, having a discharge orifice of 0.025-inch diameter, capable of discharging 3.28 gallons of water per hour with a spray angle of 90 degrees at a pressure of 100 p.s.i., shall be connected to the pressure vessel.
(3)A commercial pressurized cylinder, containing nitrogen with the customary regulators, valves, tubing, and connectors, shall be used to supply nitrogen to the pressure vessel described in paragraph
(1)of this section.
(4)Three igniting devices shall provide three different sources of ignition as follows:
(i)A metal trough with a metal cover in which cotton waste soaked in kerosene is ignited.
(ii)An electric arcing device in which the arc is produced by a 12,000-volt transformer.
(iii)A propane torch---Bernzomatic or equivalent.
(5)A means of measuring distances from the nozzle tip to the igniting device shall be provided.
(c)Test procedures.
(1)A 2 1/2-quart sample of the fluid shall be poured into the pressure vessel and heated to a temperature of 150 °F. The temperature shall be maintained at not less than 145 °F. or not more than 155 °F. during the test.
(2)Nitrogen shall be introduced into the vessel at 150 p.s.i.g.
(3)The fluid shall be sprayed at each igniting device, described in paragraph
(4)of this section, which is moved along the trajectory of the spray. Each igniting device shall be held in the spray at different distances from the nozzle tip for one minute or until the flame or arc is extinguished (if less than one minute) to determine this fire-resistant characteristic of the fluid.
(d)Appraisal of tests. If the test procedures in paragraph
(c)of this section do not result in an ignition of any sample of fluid or if an ignition of a sample does not result in flame propagation for a time interval not exceeding 6 seconds at a distance of 18 inches or more from the nozzle tip to the center of each igniting device, it shall be considered fire resistant, according to the test requirements of this section.
★   the supreme law of the land   ★
Don't Tread on Me
E Pluribus Unum — out of many, one

"If you don't know your rights, you don't have any."

Marginalia · a citizen's law index
A research desk, not legal advice. Always read the cited source before relying on a summary.
Questions or an issue? support@self-law.org
disclaimerMarginalia is a research index, not a law firm. Nothing on this site is legal, tax, or financial advice and no attorney–client relationship is formed by using it. Statutes, regulations, and case law change; summaries, search results, AI output, and member posts may be incomplete, out of date, or wrong. Any interpretation drawn from material on this site should be validated by a licensed attorney in your jurisdiction before you act on it.