§ 250.857. Glycol dehydration units.

86 words·~1 min read·/us/cfr/t30/s§ 250.857·

A research copy — for the controlling text, always check the official state or federal source. Not legal advice.

(a)You must install a pressure relief system or an adequate vent on the glycol regenerator (reboiler) to prevent over pressurization. The discharge of the relief valve must be vented in a nonhazardous manner.
(b)You must install the FSV on the dry glycol inlet to the glycol contact tower as near as practical to the glycol contact tower.
(c)You must install the shutdown valve
(SDV)on the wet glycol outlet from the glycol contact tower as near as practical to the glycol contact tower.
★   the supreme law of the land   ★
Don't Tread on Me
E Pluribus Unum — out of many, one

"If you don't know your rights, you don't have any."

Marginalia · a citizen's law index
A research desk, not legal advice. Always read the cited source before relying on a summary.
Questions or an issue? support@self-law.org
disclaimerMarginalia is a research index, not a law firm. Nothing on this site is legal, tax, or financial advice and no attorney–client relationship is formed by using it. Statutes, regulations, and case law change; summaries, search results, AI output, and member posts may be incomplete, out of date, or wrong. Any interpretation drawn from material on this site should be validated by a licensed attorney in your jurisdiction before you act on it.