Tap any paragraph to write a margin note. Your notes collect in the Desk below the text and file under cases with @. The side-by-side margin rail opens on a larger screen.

Code · CFR · Title 29 — Labor · Part 1915 · § 1915.13

§ 1915.13. Cleaning and other cold work.

795 words·~4 min read·/us/cfr/t29/s§ 1915.13·

A research copy — for the controlling text, always check the official state or federal source. Not legal advice.

(a)Locations covered by this section. The employer shall ensure that manual cleaning and other cold work are not performed in the following spaces unless the conditions of paragraph
(b)of this section have been met:
(1)Spaces containing or having last contained bulk quantities of combustible or flammable liquids or gases; and
(2)Spaces containing or having last contained bulk quantities of liquids, gases or solids that are toxic, corrosive or irritating.
(b)Requirements for performing cleaning or cold work.
(1)Liquid residues of hazardous materials shall be removed from work spaces as thoroughly as practicable before employees start cleaning operations or cold work in a space. Special care shall be taken to prevent the spilling or the draining of these materials into the water surrounding the vessel, or for shore-side operations, onto the surrounding work area.
(2)Testing shall be conducted by a competent person to determine the concentration of flammable, combustible, toxic, corrosive, or irritant vapors within the space prior to the beginning of cleaning or cold work.
(3)Continuous ventilation shall be provided at volumes and flow rates sufficient to ensure that the concentration(s) of:
(i)Flammable vapor is maintained below 10 percent of the lower explosive limit; and Note to paragraph (b)(3)(i): Spaces containing highly volatile residues may require additional ventilation to keep the concentration of flammable vapors below 10 percent of the lower explosive limit and within the permissible exposure limit.
(ii)Toxic, corrosive, or irritant vapors are maintained within the permissible exposure limits and below IDLH levels.
(4)Testing shall be conducted by the competent person as often as necessary during cleaning or cold work to assure that air concentrations are below 10 percent of the lower explosive limit and within the PELs and below IDLH levels. Factors such as, but not limited to, temperature, volatility of the residues and other existing conditions in and about the spaces are to be considered in determining the frequency of testing necessary to assure a safe atmosphere. Note to paragraph (b)(4): See appendix A for additional information on frequency of testing.
(5)Spills or other releases of flammable, combustible, toxic, corrosive, and irritant materials shall be cleaned up as work progresses.
(6)An employee may not enter a confined or enclosed space or other dangerous atmosphere if the concentration of flammable or combustible vapors in work spaces exceeds 10 percent of the lower explosive limit. Exception: An employee may enter for emergency rescue or for a short duration for installation of ventilation equipment provided:
(i)No ignition sources are present;
(ii)The atmosphere in the space is monitored continuously;
(iii)The atmosphere in the space is maintained above the upper explosive limit; and
(iv)Respiratory protection, personal protective equipment, and clothing are provided in accordance with subpart I of this part. Note to paragraph (b)(6): Other provisions for work in IDLH and other dangerous atmospheres are located in subpart I of this part.
(7)A competent person shall test ventilation discharge areas and other areas where discharged vapors may collect to determine if vapors discharged from the spaces being ventilated are accumulating in concentrations hazardous to employees.
(8)If the tests required in paragraph (b)(7) of this section indicate that concentrations of exhaust vapors that are hazardous to employees are accumulating, all work in the contaminated area shall be stopped until the vapors have dissipated or been removed.
(9)Only explosion-proof, self-contained portable lamps, or other electric equipment approved by a National Recognized Testing Laboratory
(NRTL)for the hazardous location shall be used in spaces described in paragraph
(a)of this section until such spaces have been certified as "Safe for Workers." Note to paragraph (b)(9): Battery-fed, portable lamps or other electric equipment bearing the approval of a NRTL for the class, and division of the location in which they are used are deemed to meet the requirements of this paragraph.
(10)The employer shall prominently post signs that prohibit sources of ignition within or near a space that has contained flammable or combustible liquids or gases in bulk quantities:
(i)At the entrance to those spaces;
(ii)In adjacent spaces; and
(iii)In the open area adjacent to those spaces.
(11)All air moving equipment and its component parts, including duct work, capable of generating a static electric discharge of sufficient energy to create a source of ignition, shall be bonded electrically to the structure of a vessel or vessel section or, in the case of land-side spaces, grounded to prevent an electric discharge in the space.
(12)Fans shall have non-sparking blades, and portable air ducts shall be of non-sparking materials. Note to paragraph (b): See § 1915.12(c) of this part and applicable requirements of 29 CFR part 1915, subpart Z for other provisions affecting cleaning and cold work.
Connections1 off-index
1 reference not yet in our index
  • 29 CFR 1915
Citation graph
cites case law
§ 1915.13
Cleaning and other cold work.
Cite29 CFR 1915
Cites 1Cited by 0 across 0 sources
★   the supreme law of the land   ★
Don't Tread on Me
E Pluribus Unum — out of many, one

"If you don't know your rights, you don't have any."

Marginalia · a citizen's law index
A research desk, not legal advice. Always read the cited source before relying on a summary.
Questions or an issue? support@self-law.org
disclaimerMarginalia is a research index, not a law firm. Nothing on this site is legal, tax, or financial advice and no attorney–client relationship is formed by using it. Statutes, regulations, and case law change; summaries, search results, AI output, and member posts may be incomplete, out of date, or wrong. Any interpretation drawn from material on this site should be validated by a licensed attorney in your jurisdiction before you act on it.