Tap any paragraph to write a margin note. Your notes collect in the Desk below the text and file under cases with @. The side-by-side margin rail opens on a larger screen.

Code · CFR · Title 24 — Housing and Urban Development · Part 3285 — Model Manufactured Home Installation Standards · § 3285.801

§ 3285.801. Exterior close-up.

491 words·~2 min read·/us/cfr/t24/s§ 3285.801·

A research copy — for the controlling text, always check the official state or federal source. Not legal advice.

(a)Exterior siding and roofing necessary to join all sections of the home must be installed according to the product manufacturer installation instructions and must be fastened in accordance with designs and manufacturer instructions, consistent with §§ 3280.305 and 3280.307 of this chapter. Exterior close-up strips/trim must be fastened securely and sealed with exterior sealant (see figure A to this section).
(b)Joints and seams. All joints and seams in exterior wall coverings that were disturbed during location of the home must be made weatherproof.
(c)Prior to installing the siding, the polyethylene sheeting covering exterior walls for transit must be completely removed.
(d)Prior to completing the exterior close-up, any holes in the roofing must be made weatherproof and sealed with a sealant or other material that is suitable for use with the roofing in which the hole is made.
(e)Mate-line gasket. The home manufacturer must provide materials and designs for mate-line gaskets or other methods designed to resist the entry of air, water, water vapor, insects, and rodents at all mate-line locations exposed to the exterior (see Figure B to this section).
(f)Hinged roofs and eaves. Hinged roofs and eaves must be completed during installation in compliance with all requirements of the Manufactured Home Construction and Safety Standards (24 CFR part 3280) and the Manufactured Home Procedural and Enforcement Regulations (24 CFR part 3282). Unless exempted by the following provisions, hinged roofs are also subject to a final inspection for compliance with the Manufactured Home Construction and Safety Standards (24 CFR part 3280) by the IPIA or a qualified independent inspector acceptable to the IPIA. Homes with hinged roofs that are exempted from IPIA inspection are instead to be completed and inspected in accordance with the Manufactured Home Installation Program (24 CFR part 3286). This includes homes:
(1)That are designed to be located in Wind Zone I;
(2)In which the roof pitch of the hinged roof is less than 7:12, including designs incorporating peak cap or peak flip assembly components; and
(3)In which fuel burning appliance flue penetrations are not above the hinge. Notes: 1. Multi-section homes with horizontal-lap siding can be shipped with no siding on the front and rear end walls. 2. The manufacturer must install doors/windows trimmed with J-rail or the equivalent and protect all exposed materials not designed for exposure to the weather with plastic sheeting for transport. Siding, starter trim, and vents may be shipped loose in the home for installation on set-up. 3. All home installers must ensure that all field installed trim, windows, doors, and other openings are properly sealed according to the siding manufacturer installation instructions. ``` ``` ``` Note: ``` On multi-section manufactured homes, install the sealer gasket on the ceiling, end walls, and floor mate-line prior to joining the sections together. ``` ``` \[72 FR 59362, Oct. 19, 2007, as amended at 80 FR 53731, Sept. 8, 2015; 89 FR 75758, Sept. 16, 2024\]
Connections3 off-index
3 references not yet in our index
  • 24 CFR 3280
  • 24 CFR 3282
  • 24 CFR 3286
Citation graph
cites case law
§ 3285.801
Exterior close-up.
Cite24 CFR 3280
Cite24 CFR 3282
Cite24 CFR 3286
Cites 3Cited by 0 across 0 sources
★   the supreme law of the land   ★
Don't Tread on Me
E Pluribus Unum — out of many, one

"If you don't know your rights, you don't have any."

Marginalia · a citizen's law index
A research desk, not legal advice. Always read the cited source before relying on a summary.
Questions or an issue? support@self-law.org
disclaimerMarginalia is a research index, not a law firm. Nothing on this site is legal, tax, or financial advice and no attorney–client relationship is formed by using it. Statutes, regulations, and case law change; summaries, search results, AI output, and member posts may be incomplete, out of date, or wrong. Any interpretation drawn from material on this site should be validated by a licensed attorney in your jurisdiction before you act on it.