Tap any paragraph to write a margin note. Your notes collect in the Desk below the text and file under cases with @. The side-by-side margin rail opens on a larger screen.

Code · CFR · Title 21 — Food and Drugs · Part 868 — Anesthesiology Devices · § 868.1505

§ 868.1505. Ventilatory electrical impedance tomograph.

218 words·~1 min read·/us/cfr/t21/s§ 868.1505·

A research copy — for the controlling text, always check the official state or federal source. Not legal advice.

(a)Identification. A ventilatory electrical impedance tomograph is a prescription non-invasive, non-radiological ventilatory device that provides an assessment of local impedance variation within a cross-section of a patient's thorax.
(b)Classification. Class II (special controls). The special controls for this device are:
(1)The patient-contacting components of the device must be demonstrated to be biocompatible.
(2)Non-clinical performance testing must demonstrate that the device performs as intended under anticipated conditions of use, including the following:
(i)Characterization of device parameters, including signal-to-noise ratio, voltage accuracy, drift, reciprocity accuracy, amplitude response, position error, and ringing;
(ii)Real time evaluation of local impedance variation;
(iii)Plethysmogram accuracy testing; and
(iv)Use life testing of reusable components.
(3)Performance data must validate reprocessing instructions for any reusable components of the device.
(4)Performance data must demonstrate the electrical, thermal, and mechanical safety and the electromagnetic compatibility of the device.
(5)Software verification, validation, and hazard analysis must be performed.
(6)Labeling must include the following:
(i)Guidance for interpretation of the images generated;
(ii)A warning that the device should be removed before use of a defibrillator, or defibrillator interaction information based on defibrillator performance testing with the device;
(iii)A use life for any reusable components; and
(iv)Instructions for reprocessing any reusable components. [84 FR 15098, Apr. 15, 2019]
Connections1 cite this
Cited by 1 section
Citation graph
cites case law
§ 868.1505
Ventilatory electrical impedance tomograph.
Fed. Reg.×1
Cites 0Cited by 1 across 1 source
★   the supreme law of the land   ★
Don't Tread on Me
E Pluribus Unum — out of many, one

"If you don't know your rights, you don't have any."

Marginalia · a citizen's law index
A research desk, not legal advice. Always read the cited source before relying on a summary.
Questions or an issue? support@self-law.org
disclaimerMarginalia is a research index, not a law firm. Nothing on this site is legal, tax, or financial advice and no attorney–client relationship is formed by using it. Statutes, regulations, and case law change; summaries, search results, AI output, and member posts may be incomplete, out of date, or wrong. Any interpretation drawn from material on this site should be validated by a licensed attorney in your jurisdiction before you act on it.