§ 431.110. Energy conservation standards and their effective dates.

610 words·~3 min read·/us/cfr/t10/s§ 431.110·

A research copy — for the controlling text, always check the official state or federal source. Not legal advice.

(a)Each commercial storage water heater, instantaneous water heater, and hot water supply boiler (excluding residential-duty commercial water heaters) must meet the applicable energy conservation standard level(s) as specified in the table to this paragraph. Any packaged boiler that provides service water that meets the definition of “commercial packaged boiler” in subpart E of this part, but does not meet the definition of “hot water supply boiler” in subpart G of this part, must meet the requirements that apply to it under subpart E of this part. Table 1 to § 431.110(a)—Commercial Water Heater Energy Conservation Standards Equipment Size Energy conservation standards a Minimum thermal efficiency (equipment manufactured on and after October 9, 2015) (%) Minimum thermal efficiency (equipment manufactured on and after October 6, 2026) (%) Maximum standby loss (equipment manufactured on and after October 29, 2003) b Maximum standby loss (equipment manufactured on and after October 6, 2026) b Electric storage water heatersAllN/AN/A0.30 + 27/Vm (%/h)0.30 + 27/Vm (%/h) Gas-fired storage water heaters and storage-type instantaneous water heatersAll8095Q/800 + 110(Vr) 1/2 (Btu/h)0.86 × [Q/800 + 110(Vr) 1/2] (Btu/h) Oil-fired storage water heatersAll8080Q/800 + 110(Vr) 1/2 (Btu/h)Q/800 + 110(Vr) 1/2 (Btu/h) Electric instantaneous water heaters c<10 gal ≥10 gal80 7780 77N/A 2.30 + 67/Vm (%/h)N/A 2.30 + 67/Vm (%/h) Gas-fired instantaneous water heaters and hot water supply boilers<10 gal ≥10 gal80 8096 96N/A Q/800 + 110(Vr) 1/2 (Btu/h)N/A Q/800 + 110(Vr) 1/2 (Btu/h) Oil-fired instantaneous water heater and hot water supply boilers<10 gal ≥10 gal80 7880 78N/A Q/800 + 110(Vr) 1/2 (Btu/h)N/A Q/800 + 110(Vr) 1/2 (Btu/h) a Vm is the measured storage volume, and Vr is the rated storage volume, both in gallons. Q is the rated input in Btu/h, as determined pursuant to 10 CFR 429.44. b Water heaters and hot water supply boilers with a rated storage volume greater than 140 gallons need not meet the standby loss requirement if:
(1)The tank surface area is thermally insulated to R-12.5 or more, with the R-value as defined in § 431.102
(2)A standing pilot light is not used; and
(3)For gas-fired or oil-fired storage water heaters, they have a flue damper or fan-assisted combustion. c The compliance date for energy conservation standards for electric instantaneous water heaters is January 1, 1994.
(b)Each unfired hot water storage tank manufactured on and after October 29, 2003, must have a minimum thermal insulation of R-12.5.
(c)Each residential-duty commercial water heater must meet the applicable energy conservation standard level(s) as follows: Table 2 to § 431.110(c)—Residential-Duty Commercial Water Heater Energy Conservation Standards Equipment Specifications a Draw pattern Uniform energy factor b Equipment manufactured before October 6, 2026 Equipment manufactured after October 6, 2026 Gas-fired storage>75 kBtu/hr and ≤105 kBtu/hr and ≤120 galVery Small Low Medium High0.2674−(0.0009 × Vr) 0.5362−(0.0012 × Vr) 0.6002−(0.0011 × Vr) 0.6597−(0.0009 × Vr)0.5374−(0.0009 × Vr) 0.8062−(0.0012 × Vr) 0.8702−(0.0011 × Vr) 0.9297−(0.0009 × Vr) Oil-fired storage>105 kBtu/hr and ≤140 kBtu/hr and ≤120 galVery Small Low Medium High0.2932−(0.0015 × Vr) 0.5596−(0.0018 × Vr) 0.6194−(0.0016 × Vr) 0.6470−(0.0013 × Vr)0.2932−(0.0015 × Vr) 0.5596−(0.0018 × Vr) 0.6194−(0.0016 × Vr) 0.6470−(0.0013 × Vr) Electric instantaneous>12 kW and ≤58.6 kW and ≤2 galVery Small Low Medium High0.80 0.80 0.80 0.800.80 0.80 0.80 0.80 a Additionally, to be classified as a residential-duty commercial water heater, a commercial water heater must meet the following conditions:
(1)If the water heater requires electricity, it must use a single-phase external power supply; and
(2)The water heater must not be designed to heat water to temperatures greater than 180 °F. b Vr is the rated storage volume (in gallons), as determined pursuant to 10 CFR 429.44. [88 FR 69822, Oct. 6, 2023]
Connections145 cite this · traces to 1
Cited by 145 sections · top 28
register
Citation graph
cites case law
§ 431.110
Energy conservation standards and their effective dates.
Fed. Reg.×145
Cites 1Cited by 145 across 1 source
★   the supreme law of the land   ★
Don't Tread on Me
E Pluribus Unum — out of many, one

"If you don't know your rights, you don't have any."

Marginalia · a citizen's law index
A research desk, not legal advice. Always read the cited source before relying on a summary.
Questions or an issue? support@self-law.org
disclaimerMarginalia is a research index, not a law firm. Nothing on this site is legal, tax, or financial advice and no attorney–client relationship is formed by using it. Statutes, regulations, and case law change; summaries, search results, AI output, and member posts may be incomplete, out of date, or wrong. Any interpretation drawn from material on this site should be validated by a licensed attorney in your jurisdiction before you act on it.