144.1215 AUTHORIZATION TO USE HANDHELD DENTAL X-RAY EQUIPMENT.

418 words·~2 min read·/mn/chapter-144/144-1215

A research copy — for the controlling text, always check the official state or federal source. Not legal advice.

144.1215 AUTHORIZATION TO USE HANDHELD DENTAL X-RAY EQUIPMENT.
§
Subdivision 1. Definition; handheld dental x-ray equipment.
For purposes of this section, "handheld dental x-ray equipment" means x-ray equipment that is used to take dental radiographs, is designed to be handheld during operation, and is operated by an individual authorized to take dental radiographs under chapter 150A.
§
Subd. 2. Use authorized.
(a)Handheld dental x-ray equipment may be used if the equipment:
(1)has been approved for human use by the United States Food and Drug Administration and is being used in a manner consistent with that approval; and
(2)utilizes a backscatter shield that:
(i)is composed of a leaded polymer or a substance with a substantially equivalent protective capacity;
(ii)has at least 0.25 millimeters of lead or lead-shielding equivalent; and
(iii)is permanently affixed to the handheld dental x-ray equipment.
(b)The use of handheld dental x-ray equipment is prohibited if the equipment's backscatter shield is broken or not permanently affixed to the system.
(c)The use of handheld dental x-ray equipment shall not be limited to situations in which it is impractical to transfer the patient to a stationary x-ray system.
(d)Handheld dental x-ray equipment must be stored when not in use, by being secured in a restricted, locked area of the facility.
(e)Handheld dental x-ray equipment must be calibrated initially and at intervals that must not exceed 24 months. Calibration must include the test specified in Minnesota Rules, part 4732.1100 , subpart 11.
(f)Notwithstanding Minnesota Rules, part 4732.0880 , subpart 2, item C, the tube housing and the position-indicating device of handheld dental x-ray equipment may be handheld during an exposure.
§
Subd. 3. Exemptions from certain shielding requirements.
Handheld dental x-ray equipment used according to this section and according to manufacturer instructions is exempt from the following requirements for the equipment:
(1)shielding requirements in Minnesota Rules, part 4732.0365 , item B; and
(2)requirements for the location of the x-ray control console or utilization of a protective barrier in Minnesota Rules, part 4732.0800 , subpart 2, item B, subitems
(2)and (3), provided the equipment utilizes a backscatter shield that satisfies the requirements in subdivision 2, paragraph (a), clause (2).
§
Subd. 4. Compliance with rules.
A registrant using handheld dental x-ray equipment shall otherwise comply with Minnesota Rules, chapter 4732.
§
Subd. 5. Rulemaking authority.
The commissioner shall adopt rules to implement this section. Notwithstanding section 14.125 , the authority to adopt these rules does not expire.
★   the supreme law of the land   ★
Don't Tread on Me
E Pluribus Unum — out of many, one

"If you don't know your rights, you don't have any."

Marginalia · a citizen's law index
A research desk, not legal advice. Always read the cited source before relying on a summary.
Questions or an issue? support@self-law.org
disclaimerMarginalia is a research index, not a law firm. Nothing on this site is legal, tax, or financial advice and no attorney–client relationship is formed by using it. Statutes, regulations, and case law change; summaries, search results, AI output, and member posts may be incomplete, out of date, or wrong. Any interpretation drawn from material on this site should be validated by a licensed attorney in your jurisdiction before you act on it.