Tap any paragraph to write a margin note. Your notes collect in the Desk below the text and file under cases with @. The side-by-side margin rail opens on a larger screen.

Code · Louisiana · Title 51 — Trade and Commerce

RS 51:912.24

349 words·~2 min read·/la/title-51/51-834

A research copy — for the controlling text, always check the official state or federal source. Not legal advice.

RS 51:912.24
§912.24. Installation standards for anchors and tie-downs
The following specifications are standards set for used manufactured homes when manufacturer's installation instructions and specifications are not available:
(1)Anchors:
(a)All auger anchors shall be a minimum of thirty inches in height.
(b)All anchors shall be tested to an ultimate load of four thousand seven hundred twenty-five pounds.
(2)Frame ties:
(a)Used units where the manufacturer's specifications are not available shall be anchored every ten feet in Zone I, eight feet in Zone II, and six feet in Zone III, with anchors placed within two feet of each end.
(b)Frame ties shall make at least one complete wrap around the chassis or frame and shall be looped from the top of the I-beam to the anchor. However, some frame tie straps may have to extend from the bottom of the I-beam or the I-beam on the opposite side to assure the proper angle due to the height of the home.
(c)Each frame tie shall be installed to the component manufacturer's instructions.
(d)All frame ties shall be secured to one of the main steel I-beams that run the length of the home.
(3)Marriage wall or centerline ridge beam column ties, shear wall ties, and frames ties:
(a)Multiple section homes are to be secured at the centerline with straps or cables to the specifications in the manufacturer's manual or at the locations designated on the home.
(b)Used multiple section homes shall have anchors installed at all factory-installed anchor strap connections, including ridge beam column straps, shear wall straps or attachments, or other locations designated by the manufacturer.
(4)Multiple section homes shall be mechanically fastened every twenty-four inches at the bottom, end walls, and roof. A minimum thirty-gauge, eight-inch-wide, galvanized strip shall be centered over the peak and fastened with galvanized roofing nails at two inches on center at both sides of center line.
Acts 1997, No. 970, §1; Acts 2000, 1st Ex. Sess., No. 92, §1; Acts 2001, No. 718, §2; Acts 2003, No. 661, §1; Acts 2008, No. 217, §1.
★   the supreme law of the land   ★
Don't Tread on Me
E Pluribus Unum — out of many, one

"If you don't know your rights, you don't have any."

Marginalia · a citizen's law index
A research desk, not legal advice. Always read the cited source before relying on a summary.
Questions or an issue? support@self-law.org
disclaimerMarginalia is a research index, not a law firm. Nothing on this site is legal, tax, or financial advice and no attorney–client relationship is formed by using it. Statutes, regulations, and case law change; summaries, search results, AI output, and member posts may be incomplete, out of date, or wrong. Any interpretation drawn from material on this site should be validated by a licensed attorney in your jurisdiction before you act on it.