Tap any paragraph to write a margin note. Your notes collect in the Desk below the text and file under cases with @. The side-by-side margin rail opens on a larger screen.

Code · Illinois · Chapter 425 — FIRE SAFETY · Act 55

Sec. 1.5. Stairwell door access.

514 words·~2 min read·/il/chapter-425/act-55/1-5

A research copy — for the controlling text, always check the official state or federal source. Not legal advice.

Sec. 1.5. Stairwell door access.
(a)Stairwell enclosures in buildings greater than 4 stories shall comply with one of the following requirements:
(1)no stairwell enclosure door shall be locked at any time in order to provide re-entry
from the stair enclosure to the interior of the building; or
(2)stairwell enclosure doors that are locked shall be equipped with an electronic lock
release system that is activated upon loss of power, manually by a single switch accessible to building management or firefighting personnel, and automatically by activation of the building's fire alarm system.
A telephone or other two-way communications system connected to an approved constantly attended location shall be provided on not less than every fifth floor in each stairway where the doors to the stairway are locked. If this option is selected, the building must comply with these requirements by January 1, 2006.
(b)Regardless of which option is selected under subsection
(a)of this Section, stairwell enclosure doors at the main egress level of the building shall remain unlocked from the stairwell enclosure side at all times.
(c)Building owners that select the option under paragraph
(2)of subsection
(a)of this Section must comply with the following requirements during the time necessary to install a lock release system and the two-way communication system:
(1)re-entry into the building interior shall be possible at all times on the highest
story or second highest story, whichever allows access to another exit stair;
(2)there shall not be more than 4 stories intervening between stairwell enclosure doors
that provides access to another exit stair;
(3)doors allowing re-entry shall be identified as such on the stair side of the door;
(4)doors not allowing re-entry shall be provided with a sign on the stair side
indicating the location of the nearest exit, in each direction of travel that allows re-entry; and
(5)the information required to be posted on the door under paragraphs
(3)and
(4)of
this subsection (c), shall be posted at eye level and at the bottom of the door.
(d)Nothing in this Section applies to any stairwell enclosure door that opens directly into a dwelling unit, provided the dwelling unit door has a self-closer, latch, and no self-locking hardware. Where all doors in the stairwell meet these criteria, the stairwell shall be provided with either a two-way communication system or readily operable windows on each landing or intermediate landing.
(e)Except as otherwise provided in subsection (f), a home rule unit may not regulate stairwell door access in a manner less restrictive than the regulation by the State of stairwell door access under this Act. This subsection
(e)is a limitation under subsection
(i)of Section 6 of Article VII of the Illinois Constitution on the concurrent exercise by home rule units of powers and functions exercised by the State.
(f)This Section does not apply in a home rule municipality that, on or before January 1, 2005, has passed an ordinance regulating building access from stairwell enclosures in buildings that are more than 4 stories in height.
★   the supreme law of the land   ★
Don't Tread on Me
E Pluribus Unum — out of many, one

"If you don't know your rights, you don't have any."

Marginalia · a citizen's law index
A research desk, not legal advice. Always read the cited source before relying on a summary.
Questions or an issue? support@self-law.org
disclaimerMarginalia is a research index, not a law firm. Nothing on this site is legal, tax, or financial advice and no attorney–client relationship is formed by using it. Statutes, regulations, and case law change; summaries, search results, AI output, and member posts may be incomplete, out of date, or wrong. Any interpretation drawn from material on this site should be validated by a licensed attorney in your jurisdiction before you act on it.