Code · California · Health and Safety Code

§ 9635

132 words·~1 min read·/ca/health-and-safety-code/9635

A research copy — for the controlling text, always check the official state or federal source. Not legal advice.

(a)All individual crypt openings shall be sealed with a solid panel of precast concrete, not less than 1 1 2 inches thick, fiber reinforced cement board not less than 7 16 inch thick, or other incombustible material that meets all of the following requirements:
(1)A minimum density of 80 pounds per cubic foot.
(2)A minimum modulus of rupture of 270 pounds per square inch.
(3)A minimum compressive strength of 2500 pounds per square inch.
(4)A rating that conforms to Underwriters Laboratories fire hazard class 1.
(b)All panels shall be securely set in with a high quality, nonflammable, resilient, and nonhardening urethane, silicone base, or other appropriate sealant for permanent sealing after interment is made in the crypt. Seal panels shall be set independent of crypt fronts.
★   the supreme law of the land   ★
Don't Tread on Me
E Pluribus Unum — out of many, one

"If you don't know your rights, you don't have any."

Marginalia · a citizen's law index
A research desk, not legal advice. Always read the cited source before relying on a summary.
Questions or an issue? support@self-law.org
disclaimerMarginalia is a research index, not a law firm. Nothing on this site is legal, tax, or financial advice and no attorney–client relationship is formed by using it. Statutes, regulations, and case law change; summaries, search results, AI output, and member posts may be incomplete, out of date, or wrong. Any interpretation drawn from material on this site should be validated by a licensed attorney in your jurisdiction before you act on it.