15A-3-112. Amendments to Chapters 29 through 31 of IBC.

667 words·~3 min read·/ut/title-15a/chapter-3/15a-3-112

A research copy — for the controlling text, always check the official state or federal source. Not legal advice.

Effective 7/1/2023
15A-3-112. Amendments to Chapters 29 through 31 of IBC.
(1)In IBC [P] Table 2902.1 the following changes are made:
(a)In the row for "E" occupancy in the field for "OTHER" a new footnote i is added.
(b)In the row for "I-4" occupancy in the field for "OTHER" a new footnote i is added.
(c)A new footnote g is added as follows: "FOOTNOTE: g. When provided, subject to footnote i, in public toilet facilities there shall be an equal number of diaper changing facilities in male toilet rooms and female toilet rooms."
(d)A new footnote h is added to the table as follows: "FOOTNOTE h: Non-residential child care facilities shall comply with additional sink requirements of Utah Administrative Code, R381-60-9, Hourly Child Care Centers, R381-70-9, Out of School Time Child Care Programs, and R381-100-9, Child Care Centers."
(e)A new footnote i is added to the table as follows: "FOOTNOTE i: A building owned by a state government entity or by a political subdivision of the state that allows access to the public shall provide diaper changing facilities in accordance with footnote g if:
1. the building is newly constructed; or
2. a bathroom in the building is renovated."
(f)Footnote f is deleted and replaced with the following: "FOOTNOTE f: The required number and type of plumbing fixtures for outdoor public swimming pools shall be in accordance with Utah Administrative Code, R392-302, Design, Construction and Operation of Public Pools."
(2)In IBC, Section [P] 2902.1.1, Exception 2 is deleted and replaced with the following:
"2. Where multiple-user facilities are designed to serve all genders the following shall apply:
2.1 The maximum fixture count to serve all genders shall be calculated at 50 percent of the total occupant load. The maximum fixture count for the multiple-user all gender facility shall be calculated at 50 percent female and 50 percent male.
2.2 The remaining 50 percent of the required restroom fixtures shall be provided as required by Table 2902.1 in separate toilet facilities."
(3)In IBC, Section [P] 2902.2, Exception 6 is deleted and replaced with the following:
"6. Separate facilities shall not be required as prescribed in Section 2902.1.1 Exception 2. Rooms having both water closets and lavatory fixtures designed for use by all genders and privacy for water closets shall be installed in accordance with Section 405.3.4 of the International Plumbing Code and Section 2903.1.4 of this code. Urinals in multiple-user all gender toilet facilities shall be located in an area visually separated from the remainder of the facility or each urinal that is provided shall be located in a stall and installed in accordance with Section 405.3.5 of the International Plumbing Code and Section 2903.1.5 of this code."
(4)A new IBC, Section [P]2902.8, is added as follows:
"[P]2902.8 Toilet Facilities for Workers.
Toilet facilities shall be provided for construction workers and such facilities shall be maintained in a sanitary condition. Construction worker toilet facilities of the nonsewer type shall conform to ANSI Z4.3-2016."
(5)In IBC, Section [P] 2903.1.4, the following sentence is added after the first sentence: "For restroom facilities designed to serve all genders, the partitions of the stalls shall extend from the floor to the ceiling."
(6)In IBC, Section [P] 2903.1.5, the following sentence is added at the end of the paragraph: "For facilities designed for use by all genders in the same room, urinals shall be located in a separate room or in stalls with partitions that extend from the floor to the ceiling."
(7)IBC, Section 3001.2, is deleted.
(8)In IBC, Section 3005.5, a new exception is added as follows: "Exception: Hydraulic elevators and roped hydraulic elevators with a rise of 50 feet or less."
(9)In IBC, Section 3109.1, the words "the International Swimming Pool and Spa Code" at the end of the section are deleted and replaced with the words "Utah Administrative Code, R392-302, Design, Construction and Operation of Public Pools."
Amended by Chapter 209 , 2023 General Session
★   the supreme law of the land   ★
Don't Tread on Me
E Pluribus Unum — out of many, one

"If you don't know your rights, you don't have any."

Marginalia · a citizen's law index
A research desk, not legal advice. Always read the cited source before relying on a summary.
Questions or an issue? support@self-law.org
disclaimerMarginalia is a research index, not a law firm. Nothing on this site is legal, tax, or financial advice and no attorney–client relationship is formed by using it. Statutes, regulations, and case law change; summaries, search results, AI output, and member posts may be incomplete, out of date, or wrong. Any interpretation drawn from material on this site should be validated by a licensed attorney in your jurisdiction before you act on it.