Tap any paragraph to write a margin note. Your notes collect in the Desk below the text and file under cases with @. The side-by-side margin rail opens on a larger screen.

Code · REGISTER · 2019-07-11 · PROPOSED RULES · Agency Health Agency for Healthcare Research and Quality NOTICES Agency Information Collection Activities; Proposals, Submissions, and Approvals, 33069-33073 2019-14770 Agriculture Agriculture Departm · Unknown

Unknown. Final special conditions

7,055 words·~32 min read·/register/2019/07/11/2019-14784

A research copy — for the controlling text, always check the official state or federal source. Not legal advice.

--- schema: federal-register doc_type: fedreg source_file: FR-2019-07-11.xml --- 84 133 Thursday, July 11, 2019 Contents Agency Health Agency for Healthcare Research and Quality NOTICES Agency Information Collection Activities; Proposals, Submissions, and Approvals, 33069-33073 2019-14770 Agriculture Agriculture Department NOTICES Agency Information Collection Activities; Proposals, Submissions, and Approvals, 33051 2019-14750 Civil Rights Civil Rights Commission NOTICES Meetings:
Utah Advisory Committee, 33051-33052 2019-14777 Meetings; Sunshine Act, 33052 2019-14803 Commerce Commerce Department See International Trade Administration See National Oceanic and Atmospheric Administration Corporation Corporation for National and Community Service NOTICES Agency Information Collection Activities; Proposals, Submissions, and Approvals: Application Package for AmeriCorps National Civilian Community Corps Member Experience Survey, 33063-33064 2019-14761 Employment and Training Employment and Training Administration NOTICES Program Year 2019 Workforce Innovation and Opportunity Act Section 167, National Farmworker Jobs Program Grantee Allotments, 33087-33090 2019-14731 Energy Department Energy Department See Federal Energy Regulatory Commission PROPOSED RULES Energy Conservation Program for Appliance Standards:
Energy Conservation Standards for Residential Furnaces and Commercial Water Heaters, 33011-33022 2019-14553 NOTICES Meetings: Environmental Management Site-Specific Advisory Board, Savannah River Site, 33064 2019-14753 Environmental Protection Environmental Protection Agency RULES Air Quality State Implementation Plans; Approvals and Promulgations: Arizona; Regional Haze Progress Report, 33002-33004 2019-14692 Illinois, Indiana; Revised Designation of Illinois and Indiana 2012 PM <sup>2.5</sup> Unclassifiable Areas, 33008 C1--2018--27903 Kentucky:
Jefferson County Existing and New VOC Water Separators Rule Revision, 33004-33006 2019-14631 Maryland; Basic Inspection and Maintenance Program Certification State Implementation Plan for the Baltimore Nonattainment Area Under the 2008 Ozone National Ambient Air Quality Standard, 33006-33008 2019-14691 PROPOSED RULES Air Quality State Implementation Plans; Approvals and Promulgations: California; Yolo-Solano Air Quality Management District; Stationary Source Permits, 33030-33032 2019-14629 District of Columbia;
Reasonably Available Control Technology State Implementation Plan for Volatile Organic Compounds under the 2008 Ozone National Ambient Air Quality Standard, 33032-33035 2019-14628 Georgia; 2008 8-hour Ozone Interstate Transport, 33027-33030 2019-14729 Nevada; Revisions to Clark County Ozone Maintenance Plan, 33035-33045 2019-14630 National Oil and Hazardous Substances Pollution Contingency Plan; National Priorities List: Deletion of the Electro-Coatings, Inc. Superfund Site, 33046-33050 2019-14759 National Primary Drinking Water Regulations:
Perchlorate, 33045 C1--2019--12773 Public Water System Supervision Program Revisions for Delaware, 33045-33046 2019-14632 Federal Aviation Federal Aviation Administration RULES Airworthiness Directives: Saab AB, Saab Aeronautics (Formerly Known as Saab AB, Saab Aerosystems) Airplanes, 32980-32982 2019-14726 Special Conditions: TTF Aerospace, LLC, Airbus Model A330-300 and Model A330-900 Series Airplanes; Bulk Cargo Lower Deck Crew Rest Compartments, 32975-32980 2019-14784 PROPOSED RULES Amendment of the Class E Airspace:
Haleyville, AL, and Hamilton, AL, 33022-33024 2019-14633 NOTICES Petitions for Exemptions; Summaries: L. Salcedo, 33116-33117 2019-14776 Request to Release Airport Property for Land Disposal, 33115-33116 2019-14634 Federal Communications Federal Communications Commission NOTICES Meeting, 33067-33068 2019-14722 FCAH Federal Council on the Arts and the Humanities NOTICES Meetings: Arts and Artifacts Indemnity Panel Advisory Committee, 33092-33093 2019-14751 Federal Deposit Federal Deposit Insurance Corporation NOTICES Termination of Receivership, 33068-33069 2019-14746 Federal Election Federal Election Commission NOTICES Meetings;
Sunshine Act, 33069 2019-14893 Federal Emergency Federal Emergency Management Agency NOTICES Agency Information Collection Activities; Proposals, Submissions, and Approvals: Citizen Responder Programs Registration, 33083-33084 2019-14766 Federal Energy Federal Energy Regulatory Commission NOTICES Application: Cornell University, 33064-33065 2019-14735 Environmental Assessments; Availability, etc.: Bluewater Gas Storage, LLC; Bluewater Compression Project, 33066-33067 2019-14734 Filing:
Northern Indiana Public Service Co., 33065 2019-14736 Federal Highway Federal Highway Administration NOTICES Agency Information Collection Activities; Proposals, Submissions, and Approvals, 33117 2019-14757 Federal Railroad Federal Railroad Administration NOTICES Petition for Waiver of Compliance, 33117-33118 2019-14783 Fiscal Fiscal Service NOTICES Agency Information Collection Activities; Proposals, Submissions, and Approvals: U.S. Treasury Auction Submitter Agreement, 33118 2019-14754 Fish Fish and Wildlife Service NOTICES Agency Information Collection Activities;
Proposals, Submissions, and Approvals: Implementing Regulations for Petitions, 33084-33086 2019-14763 Food and Drug Food and Drug Administration RULES New Animal Drugs; Updating Tolerances for Residues of New Animal Drugs in Food, 32982-33002 2019-14098 NOTICES Guidance: Harmonizing Compendial Standards With Drug Application Approval Using the United States Pharmacopeial Convention Pending Monograph Process, 33073-33075 2019-14781 Live Case Presentations During Investigational Device Exemption Clinical Trials, 33075-33077 2019-14765 Using the Inactive Ingredient Database, 33077-33078 2019-14780 Meetings:
Allergenic Products Advisory Committee; Correction, 33078 2019-14779 Foreign Assets Foreign Assets Control Office RULES North Korea Sanctions, 33002 C1--2019--13652 Health and Human Health and Human Services Department See Agency for Healthcare Research and Quality See Food and Drug Administration See Health Resources and Services Administration See National Institutes of Health Health Resources Health Resources and Services Administration NOTICES Agency Information Collection Activities;
Proposals, Submissions, and Approvals: Children's Hospitals Graduate Medical Education Payment Program, 33079-33080 2019-14752 Meetings: Advisory Committee on Heritable Disorders in Newborns and Children, 33078-33079 2019-14758 Homeland Homeland Security Department See Federal Emergency Management Agency Interior Interior Department See Fish and Wildlife Service See Reclamation Bureau Internal Revenue Internal Revenue Service RULES Organizations under Common Control; Eighty Percent Control Test for a Brother-Sister Controlled Group;
Correcting Amendment, 33002 2019-14424 PROPOSED RULES Guidance on Passive Foreign Investment Companies, 33120-33161 2019-12030 International Trade Adm International Trade Administration NOTICES Antidumping or Countervailing Duty Investigations, Orders, or Reviews: Certain Quartz Surface Products from the People's Republic of China, 33053-33060 2019-14865 Stainless Steel Butt-Weld Pipe Fittings from Italy, 33052-33053 2019-14762 Labor Department Labor Department See Employment and Training Administration NOTICES Agency Information Collection Activities;
Proposals, Submissions, and Approvals: National Childcare Costs Database, 33091 2019-14730 Pharmacy Billing Requirements, 33091-33092 2019-14741 National Foundation National Foundation on the Arts and the Humanities See Federal Council on the Arts and the Humanities National Institute National Institutes of Health NOTICES Meetings: Center for Scientific Review, 33082 2019-14737 National Institute of Allergy and Infectious Diseases, 33082 2019-14740 National Institute of Diabetes and Digestive and Kidney Diseases, 33081-33082 2019-14739 2019-14742 National Institute of Environmental Health Sciences, 33082-33083 2019-14743 National Institute on Deafness and Other Communication Disorders, 33081 2019-14744 National Institute on Drug Abuse, 33081 2019-14738 National Oceanic National Oceanic and Atmospheric Administration RULES Atlantic Highly Migratory Species:
Atlantic Bluefin Tuna Fisheries, 33008-33010 2019-14778 NOTICES Endangered and Threatened Species: Take of Anadromous Fish, 33062-33063 2019-14771 Meetings: Evaluation of North Inlet Winyah Bay National Estuarine Research Reserve, 33061 2019-14733 Permit Application: General Provisions for Domestic Fisheries; Exempted Fishing, 33060-33062 2019-14727 2019-14728 Nuclear Regulatory Nuclear Regulatory Commission NOTICES License Amendment Request: Tennessee Valley Authority; Browns Ferry Nuclear Plant, Units 1, 2, and 3, 33094-33097 2019-14764 Post-Shutdown Decommissioning Activities Report:
Exelon Generation Co., LLC; Three Mile Island Nuclear Station Unit 1, 33093-33094 2019-14745 Peace Peace Corps NOTICES Agency Information Collection Activities; Proposals, Submissions, and Approvals, 33097 2019-14718 Reclamation Reclamation Bureau NOTICES Quarterly Status Report of Water Service, Repayment, and Other Water-Related Contract Actions, 33086-33087 2019-14725 Securities Securities and Exchange Commission PROPOSED RULES List of Rules to be Reviewed Pursuant to the Regulatory Flexibility Act, 33024-33027 2019-14616 NOTICES Self-Regulatory Organizations;
Proposed Rule Changes: Financial Industry Regulatory Authority, Inc., 33098-33102 2019-14724 The Nasdaq Stock Market, LLC, 33102-33113 2019-14723 Small Business Small Business Administration NOTICES Agency Information Collection Activities; Proposals, Submissions, and Approvals: Generic Information Collection under Circular A-11, Section 280: Improving Customer Service, 33113-33114 2019-14749 Disaster Declaration: Indiana, 33114 2019-14760 Surface Transportation Surface Transportation Board NOTICES Abandonment Exemption;
Discontinuance Exemption: CSX Transportation, Inc., Allegheny County, PA; Allegheny Valley Railroad Co., Allegheny County, PA, 33115 2019-14747 Environmental Assessments; Availability, etc.: Northern Columbia Basin Railroad Project, 33114-33115 2019-14826 Transportation Department Transportation Department See Federal Aviation Administration See Federal Highway Administration See Federal Railroad Administration Treasury Treasury Department See Fiscal Service See Foreign Assets Control Office See Internal Revenue Service Separate Parts In This Issue Part II Treasury Department, Internal Revenue Service, 33120-33161 2019-12030 Reader Aids Consult the Reader Aids section at the end of this issue for phone numbers, online resources, finding aids, and notice of recently enacted public laws.
To subscribe to the Federal Register Table of Contents electronic mailing list, go to https://public.govdelivery.com/accounts/USGPOOFR/subscriber/new, enter your e-mail address, then follow the instructions to join, leave, or manage your subscription. 84 133 Thursday, July 11, 2019 Rules and Regulations DEPARTMENT OF TRANSPORTATION Federal Aviation Administration 14 CFR Part 25 [Docket No. FAA-2019-0427; Special Conditions No. 25-752-SC] Special Conditions: TTF Aerospace, LLC, Airbus Model A330-300 and Model A330-900 Series Airplanes;
Bulk Cargo Lower Deck Crew Rest Compartments AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Final special conditions. SUMMARY: These special conditions are issued for the Airbus Model A330-300 and Model A330-900 series airplanes. These airplanes, as modified by TTF Aerospace, LLC (TTF Aerospace), will have a novel or unusual design feature when compared to the state of technology envisioned in the airworthiness standards for transport category airplanes. This design feature is a lower deck mobile crew rest (LD-MCR) compartment installed in the aft cargo compartment of Model A330&ndash;300 and Model A330-900 series airplanes.
The applicable airworthiness regulations do not contain adequate or appropriate safety standards for this design feature. These special conditions contain the additional safety standards that the Administrator considers necessary to establish a level of safety equivalent to that established by the existing airworthiness standards. DATES: Effective July 11, 2019. FOR FURTHER INFORMATION CONTACT: Alan Sinclair, Airframe & Cabin Safety Section, AIR-675, Transport Standards Branch, Policy and Innovation Division, Aircraft Certification Service, Federal Aviation Administration, 2200 South 216th Street, Des Moines, Washington 98198; telephone and fax 206-231-3215; email *alan.sinclair@faa.gov.* SUPPLEMENTARY INFORMATION:
Background On February 20, 2019, TTF Aerospace applied for a supplemental type certificate for a LD-MCR installed in the aft cargo compartment of Airbus Model A330-300 and Model A330-900 series airplanes. The Airbus Model A330-300 and Model A330-900 series airplanes are twin engine, transport category airplanes with maximum takeoff weights of 405,650 and 533,518 pounds, respectively, and seating for 440 passengers. The LD-MCR compartment will be located under the passenger cabin floor in the aft cargo compartment of Airbus Model A330-300 and Model A330-900 airplanes.
It will be removable from the cargo compartment. The LD-MCR compartment will be occupied in flight but not during taxi, takeoff, or landing. No more than ten crewmembers at a time will be permitted to occupy it. The LD-MCR compartment will have a smoke detection system, a fire suppression system, and an oxygen system. The LD-MCR compartment will be accessed from the main deck via a “stairhouse.” The floor within the stairhouse has a hatch that leads to stairs that occupants use to descend into the LD-MCR compartment.
An interface will keep this hatch open when the stairhouse door is open. In addition, there will be an emergency hatch that opens directly into the main passenger cabin. The LD-MCR compartment has a maintenance door. This door is intended to be used to allow maintenance personnel and cargo handlers to enter the LD-MCR from the cargo compartment when the airplane is not in flight. Type Certification Basis Under the provisions of title 14, Code of Federal Regulations (14 CFR) 21.101, TTF Aerospace must show that the Airbus Model A330-300 and Model A330-900 series airplanes, as changed, continue to meet the applicable provisions of the regulations listed in Type Certificate No.
A46NM or the applicable regulations in effect on the date of application for the change, except for earlier amendments as agreed upon by the FAA. If the Administrator finds that the applicable airworthiness regulations ( *i.e.,* 14 CFR part 25) do not contain adequate or appropriate safety standards for the Airbus Model A330-300 and Model A330-900 series airplanes because of a novel or unusual design feature, special conditions are prescribed under the provisions of § 21.16. Special conditions are initially applicable to the model for which they are issued.
Should the applicant apply for a supplemental type certificate to modify any other model included on the same type certificate to incorporate the same novel or unusual design feature, these special conditions would also apply to the other model under § 21.101. In addition to the applicable airworthiness regulations and special conditions, the Airbus Model A330-300 and Model A330-900 series airplanes must comply with the fuel vent and exhaust emission requirements of 14 CFR part 34 and the noise certification requirements of 14 CFR part 36.
The FAA issues special conditions, as defined in 14 CFR 11.19, in accordance with § 11.38, and they become part of the type certification basis under § 21.101. Novel or Unusual Design Features The Airbus Model A330-300 and Model A330-900 series airplanes will incorporate the following novel or unusual design features: This design feature is a LD-MCR compartment installed in the aft cargo compartment of Airbus Model A330 300 and Model A330-900 series airplanes. Discussion While the installation of the crew rest compartment is not a new concept for large transport category airplanes, each crew rest compartment has unique features based on design, location, and use on the airplane.
The LD-MCR compartment is novel in terms of part 25 of title 14 of the CFR in that it will be located under the passenger cabin floor in the aft cargo compartment of Airbus Model A330-300 and Model A330-900 series airplanes, which is not contemplated by § 25.819 regarding lower deck service compartments (including galleys). Due to the novel or unusual features associated with the installation of a LD-MCR compartment, special conditions are considered necessary to provide a level of safety equal to that established by the airworthiness regulations incorporated by reference in the type certificates of these airplanes, as applicable airworthiness regulations do not contain adequate or appropriate safety standards for this design feature.
Most of these special conditions come from § 25.819, but they require more stringent standards for fire protection and emergency egress because of design features and location of the LD-MCR. The applicant should note that the FAA considers smoke or fire detection and fire suppression systems (including airflow management features that prevent hazardous quantities of smoke or fire extinguishing agent from entering any other compartment occupied by crewmembers or passengers) for crew rest compartments complex in terms of paragraph 6d of Advisory Circular
(AC)25.1309-1A, “System Design and Analysis,” dated June 21, 1988. In addition, the FAA considers failure of the crew rest compartment fire protection system ( *i.e.,* smoke or fire detection and fire suppression systems) in conjunction with a crew rest fire to be a catastrophic event. Based on the “Depth of Analysis Flowchart” shown in Figure 2 of AC 25.1309-1A, the depth of analysis should include both qualitative and quantitative assessments. Refer to paragraphs 8d, 9, and 10 of AC 25.1309-1A. Note that flammable fluids, explosives, or other dangerous cargo are prohibited from being carried in the crew rest areas. The requirements to enable crewmembers' quick entry to the crew rest compartment, and to locate a fire source, inherently places limits on the amount of baggage that may be carried and the size of the crew rest area. The FAA considers that the crew rest area must be limited to the stowage of crew personal luggage and both must not be used for the stowage of cargo or passenger baggage. The design of such a system to include cargo or passenger baggage would require additional requirements to ensure safe operation. Furthermore, the addition of galley equipment, or a kitchenette incorporating a heat source ( *e.g.,* cook tops, microwaves, coffee pots, etc.), other than a conventional lavatory or kitchenette hot water heater, within the LD-MCR compartment defined in the “Novel or Unusual Design Features” section, may require additional special conditions to be considered. A hot water heater is acceptable without further special conditions consideration. Finally, amendment 25-38 modified the requirements of § 25.1439(a) by adding, “In addition, protective breathing equipment must be installed in each isolated separate compartment in the airplane, including upper and lower lobe galleys, in which crewmember occupancy is permitted during flight for the maximum number of crewmembers expected to be in the area during any operation.” The LD-MCR compartment is an isolated separate compartment, so § 25.1439(a) is applicable. However, the § 25.1439(a) protective breathing equipment
(PBE)requirements for isolated separate compartments are not appropriate because the LD-MCR compartment is novel or unusual in terms of the number of occupants. In 1976, when amendment 25-38 was adopted, small galleys were the only isolated compartments that had been certificated. Two crewmembers were the maximum expected to occupy those galleys. This crew rest compartment can accommodate up to ten crewmembers. This large number of occupants in an isolated compartment was not envisioned at the time amendment 25-38 was adopted. It is not appropriate for all occupants to don PBEs in the event of a fire because the first action should be to leave the confined space unless the occupant is fighting the fire. Taking the time to don the PBE would prolong the time for the emergency evacuation of the occupants and possibly interfere with efforts to extinguish the fire. These special conditions therefore provide procedures that establish a level of safety equivalent to the PBE requirements. Operational Evaluations and Approval These special conditions outline requirements for flightcrew and cabin crew rest compartment design approvals ( *e.g.,* type design change or supplemental type certificate) administered by the FAA's Aircraft Certification Service. Prior to operational use of a flight (cabin) crew rest compartment, the FAA's Flight Standards Service must evaluate, for operational suitability the flight (cabin) crew sleeping quarters and rest facilities. Refer to §§ 91.1061(b)(1), 121.485(a), 121.523(b), and 135.269(b)(5). Compliance with these special conditions does not ensure that the applicant has demonstrated compliance with the requirements of 14 CFR part 91, 121, or 135. To obtain an operational evaluation, the type design holder must contact the appropriate Aircraft Evaluation Group
(AEG)in the Flight Standards Service and request an evaluation for operational suitability of the flightcrew sleeping quarters in their crew rest facility. Results of these evaluations should be documented and appended to the applicable Flight Standardization Board Report. Individual operators may reference these standardized evaluations in discussions with their FAA Principal Operating Inspector as the basis for an operational approval, in lieu of an on-site operational evaluation. Any changes to the approved flight (cabin) crew rest compartment configuration that affect crewmember emergency egress or any other procedures affecting the safety of the occupying crewmembers and/or related training shall require a re-evaluation and approval. In the event of any design change that affects egress, safety procedures, or training, the applicant is responsible for notifying the FAA's AEG that a new crew rest facility evaluation is required. All instructions for continued airworthiness
(ICAs)will be submitted to the Seattle AEG for approval acceptance, including service bulletins, before issuance of the FAA modification approval. These special conditions are the same as Special Conditions 25-281-SC, except the maximum occupancy is ten rather than seven occupants, and a change to the table in Special Condition 20. The conditions provide an appropriate level of safety for the occupancy limit as only the size of the compartment will increase to accommodate the additional occupants, but all other requirements for safety, fire suppression, and emergency evacuation will remain the same. In addition, the change to the table in Special Condition 20 is related to the location of the crew rest and specifics of the crew rest design. Stowage compartments located in the vicinity of critical equipment or located in an overhead area would typically be listed as conditional. However, this LD-MCR compartment is located in the Class C cargo compartment with all of its features that provide fire protection ( *e.g.,* the use of liner material that meets appendix F to part 25, part III; control of ventilation; active fire suppression; active fire detection; etc.). These features remain when the crew rest is installed. These special conditions contain the additional safety standards that the Administrator considers necessary to establish a level of safety equivalent to that established by the existing airworthiness standards. Discussion of Comments The FAA issued Notice of Proposed Special Conditions No. 25-19-07-SC for the Airbus Model A330-300 and Model A330-900 series airplane, which was published in the **Federal Register** on June 7, 2019 (84 FR 26593). No comments were received, and the special conditions are adopted as proposed. Applicability As discussed above, these special conditions are applicable to the Airbus Model A330-300 and Model A330-900 airplanes. Should TTF Aerospace apply at a later date for a supplemental type certificate to modify any other model included on Type Certificate No. A46NM to incorporate the same novel or unusual design feature, these special conditions would apply to that model as well. Under standard practice, the effective date of final special conditions would be 30 days after the date of publication in the **Federal Register** . However, as the certification date for the LD-MCR compartment is currently scheduled for July 2019 for the Airbus Model A330-300 and Model A330-900 airplanes is imminent, the FAA finds that good cause exists to make these special conditions effective upon publication. Conclusion This action affects only a certain novel or unusual design feature on Airbus Model A330-300 and Model A330-900 of airplanes as modified by TTF Aerospace. It is not a rule of general applicability and affects only the applicant who applied to the FAA for approval of these features on the airplane. List of Subjects in 14 CFR Part 25 Aircraft, Aviation safety, Reporting and recordkeeping requirements. Authority Citation The authority citation for these special conditions is as follows: Authority: 49 U.S.C. 106(f), 106(g), 40113, 44701, 44702, 44704. The Special Conditions Accordingly, pursuant to the authority delegated to me by the Administrator, the following special conditions are issued as part of the type certification basis for Airbus Model A330-300 and Model A330-900 airplanes, as modified by TTF Aerospace. 1. Occupancy of the LD-MCR compartment is limited to the total number of installed bunks and seats in each compartment. For each occupant permitted in the LD-MCR compartment, there must be an approved seat or berth able to withstand the maximum flight loads when occupied. The maximum occupancy in the LD-MCR compartment is ten. a. There must be appropriate placards displayed in a conspicuous place at each entrance to the LD-MCR compartment indicating the following information:
(1)The maximum number of occupants allowed;
(2)That occupancy is restricted to crewmembers trained in the evacuation procedures for the LD-MCR compartment;
(3)That occupancy is prohibited during taxi, takeoff and landing;
(4)That smoking is prohibited in the LD-MCR compartment; and
(5)That the LD-MCR compartment is limited to the stowage of personal luggage of crewmembers and must not be used for the stowage of cargo or passenger baggage. b. There must be at least one ashtray located conspicuously on or near the entry side of any entrance to the LD-MCR compartment. c. There must be a means to prevent passengers from entering the LD-MCR compartment in an emergency or when no flight attendant is present. d. There must be a means for any door installed between the LD-MCR compartment and the passenger cabin to be capable of being quickly opened from inside the LD-MCR compartment, even when crowding occurs at each side of the door. e. For all doors installed in the evacuation routes, there must be a means to preclude anyone from being trapped inside a compartment. If a locking mechanism is installed, it must be capable of being unlocked from the outside without the aid of special tools. The lock must not prevent opening from the inside of a compartment at any time. 2. There must be at least two emergency evacuation routes, which could be used by each occupant of the LD-MCR compartment to rapidly evacuate to the main cabin and could be closed from the main passenger cabin after evacuation. a. The routes must be located with one at each end of the LD-MCR compartment or with two having sufficient separation within the LD-MCR compartment and between the routes to minimize the possibility of an event (either inside or outside of the LD-MCR compartment) rendering both routes inoperative. b. The routes must be designed to minimize the possibility of blockage, which might result from fire, mechanical or structural failure, or from persons standing on top of or against the escape route. If an evacuation route utilizes an area where normal movement of passengers occurs, it must be demonstrated that passengers would not impede egress to the main deck. If a hatch is installed in an evacuation route, the point at which the evacuation route terminates in the passenger cabin should not be located where normal movement by passengers or crew occur, such as in a main aisle, cross aisle, passageway, or galley complex. If such a location cannot be avoided, special consideration must be taken to ensure that the hatch or door can be opened when a person who is the weight of a ninety-fifth percentile male is standing on the hatch or door. The use of evacuation routes must not be dependent on any powered device. If there is low headroom at or near an evacuation route, provision must be made to prevent or to protect occupants of the LD-MCR compartment from head injury. c. Emergency evacuation procedures, including the emergency evacuation of an incapacitated crewmember from the LD-MCR compartment, must be established. All of these procedures must be transmitted to the operator for incorporation into its training programs and appropriate operational manuals. d. There must be a limitation in the Airplane Flight Manual or other suitable means requiring that crewmembers be trained in the use of evacuation routes. 3. There must be a means for the evacuation of an incapacitated crewmember who is representative of a 95th percentile male from the LD-MCR compartment to the passenger cabin floor. The evacuation must be demonstrated for all evacuation routes. A flight attendant or other crewmember (a total of one assistant within the LD-MCR compartment) may provide assistance in the evacuation. Additional assistance may be provided by up to three persons in the main passenger compartment. For evacuation routes having stairways, the additional assistants may descend down to one half the elevation change from the main deck to the LD-MCR compartment or to the first landing, whichever is higher. 4. The following signs and placards must be provided in the LD-MCR compartment: a. At least one exit sign that meets the requirements of § 25.812(b)(1)(i) at amendment 25-58 must be located near each exit. However, a sign with reduced background area of no less than 5.3 square inches (excluding the letters) may be utilized, provided that it is installed such that the material surrounding the exit sign is light in color ( *e.g.,* white, cream, light beige). If the material surrounding the exit sign is not light in color, a sign with a minimum of a one-inch wide background border around the letters would also be acceptable; b. An appropriate placard that defines the location and the operating instructions for each evacuation route must be located near each exit; c. Placards must be readable from a distance of 30 inches under emergency lighting conditions; and d. The exit handles and the placards with the evacuation path operating instructions must be illuminated to at least 160 microlamberts under emergency lighting conditions. 5. There must be a means for emergency illumination to be automatically provided for the LD-MCR compartment in the event of failure of the main power system of the airplane or of the normal lighting system of the LD-MCR compartment. a. This emergency illumination must be independent of the main lighting system. b. The sources of general cabin illumination may be common to both the emergency and the main lighting systems, if the power supply to the emergency lighting system is independent of the power supply to the main lighting system. c. The illumination level must be sufficient for the occupants of the LD-MCR compartment to locate and transfer to the main passenger cabin floor by means of each evacuation route. d. The illumination level must be sufficient to locate a deployed oxygen mask with the privacy curtains in the closed position for each occupant of the LD-MCR compartment. 6. There must be means for two-way voice communications between crewmembers on the flightdeck and crewmembers in the LD-MCR compartment. Section 25.785(h) at amendment 25-51 requires flight attendant seats near required floor level emergency exits. Each such exit seat on the aircraft must have a public address system microphone that allows two-way voice communications between flight attendants and crewmembers in the LD-MCR compartment. One microphone may serve more than one such exit seat, provided the proximity of the exits allows unassisted verbal communications between seated flight attendants. 7. There must be a means for manual activation of an aural emergency alarm system, audible during normal and emergency conditions, to enable crewmembers on the flightdeck and at each pair of required floor-level emergency exits to alert crewmembers in the LD-MCR compartment of an emergency. Use of a public address or crew interphone system will be acceptable, provided an adequate means of differentiating between normal and emergency communications is incorporated. The system must be powered in flight for at least ten minutes after the shutdown or failure of all engines and auxiliary power units
(APU)or the disconnection or failure of all power sources that are dependent on the continued operation of the engines and APUs. 8. There must be a means, readily detectable by seated or standing occupants of the LD-MCR compartment, which indicates when seat belts should be fastened. If there are no seats, at least one means, such as sufficient handholds, must be provided to cover anticipated turbulence. Seat belt-type restraints must be provided for berths and must be compatible with the sleeping attitude during cruise conditions. There must be a placard on each berth indicating that seat belts must be fastened when the berth is occupied. If compliance with any of the other requirements of these special conditions is predicated on specific head location, there must be a placard specifying the head position. 9. To provide a level of safety equivalent to that provided to occupants of a small isolated galley, in lieu of the requirements of § 25.1439(a) at amendment 25-38 that pertain to isolated compartments, the following equipment must be provided in the LD-MCR compartment: a. At least one approved hand-held fire extinguisher appropriate for the kinds of fires likely to occur; b. Two portable Protective Breathing Equipment
(PBE)units, approved to Technical Standard Order TSO-C116 or equivalent, which are suitable for fire-fighting, or one PBE for each hand-held fire extinguisher, whichever is greater; and c. One flashlight. Note: Additional PBEs and fire extinguishers in specific locations, beyond the minimum numbers prescribed in Special Condition 9, may be required as a result of any egress analysis accomplished to satisfy Special Condition 2(a). 10. A smoke or fire detection system or systems must be provided to monitor each occupiable area within the LD-MCR compartment, including those areas partitioned by curtains. Flight tests must be conducted to show compliance with this requirement. Each smoke or fire detection system must provide the following: a. A visual indication to the flightdeck within one minute after the start of a fire; b. An aural warning in the LD-MCR compartment; and c. A warning in the main passenger cabin. This warning must be readily detectable by a flight attendant, taking into consideration the positioning of flight attendants throughout the main- passenger compartment during various phases of flight. 11. The LD-MCR compartment must be designed such that fires within it can be controlled without a crewmember having to enter the compartment or be designed such that crewmembers equipped for fire-fighting have unrestricted access to the compartment. The time for a crewmember on the main deck to react to the fire alarm, don the fire-fighting equipment, and gain access must not exceed the time for the compartment to become smoke-filled, making it difficult to locate the source of the fire. 12. There must be a means provided to exclude hazardous quantities of smoke or extinguishing agent originating in the LD-MCR compartment from entering any other compartment occupied by crewmembers or passengers. This means must include the time periods during the evacuation of the LD-MCR compartment and, if applicable, when accessing the LD-MCR compartment to manually fight a fire. Smoke entering any other compartment occupied by crewmembers or passengers when the LD-MCR compartment is opened during an emergency evacuation must dissipate within five minutes after the LD-MCR compartment is closed. Hazardous quantities of smoke may not enter any other compartment occupied by crewmembers or passengers during subsequent access to manually fight a fire in the LD-MCR compartment. (The amount of smoke entrained by a firefighter exiting the LD-MCR compartment through the access is not considered hazardous.) During the one-minute smoke detection time, penetration of a small quantity of smoke from the LD-MCR compartment into an occupied area is acceptable. Flight tests must be conducted to show compliance with this requirement. If a built-in fire suppression system is used in lieu of manual firefighting, the fire suppression system must be designed so that no hazardous quantities of extinguishing agent will enter other compartments occupied by passengers or crewmembers. The system must have adequate capacity to suppress any likely fire occurring in the LD-MCR compartment, considering the fire threat, the volume of the compartment and the ventilation rate. 13. For each seat and berth in the LD-MCR compartment, there must be a supplemental oxygen system equivalent to that provided for main deck passengers. The system must provide an aural and visual warning to alert the occupants of the LD-MCR compartment of the need to don oxygen masks in the event of decompression. The warning must activate before the cabin pressure altitude exceeds 15,000 feet. The aural warning must sound continuously for a minimum of five minutes or until a reset push button in the LD-MCR compartment is depressed. Procedures for crewmembers in the LD-MCR compartment to follow in the event of decompression must be established. These procedures must be transmitted to the operator for incorporation into their training programs and appropriate operational manuals. 14. The following requirements apply to LD-MCR compartments that are divided into several sections by the installation of curtains or doors: a. To warn crewmembers who may be sleeping, there must be an aural alert that accompanies automatic presentation of supplemental oxygen masks. The alert must be able to be heard in each section of the LD-MCR compartment. A visual indicator that occupants must don an oxygen mask is required in each section where seats or berths are not installed. A minimum of two supplemental oxygen masks are required for each seat or berth. There must also be a means to manually deploy the oxygen masks from the flightdeck. b. A placard is required adjacent to each curtain that visually divides or separates the LD-MCR compartment into small sections for privacy purposes. The placard must indicate that the curtain is to remain open when the private section it creates is unoccupied. c. For each section created by the installation of a curtain, the following requirements of these special conditions must be met both with the curtain open and with the curtain closed:
(1)Emergency illumination (Special Condition 5);
(2)Aural emergency alarm (Special Condition 7);
(3)Fasten seat belt signal or return to seat signal as applicable (Special Condition 8); and
(4)Smoke or fire detection (Special Condition 10). d. Crew rest compartments visually divided to the extent that evacuation could be affected must have exit signs that direct occupants to the primary stairway exit. The exit signs must be provided in each separate section of the LD-MCR compartment and must meet the requirements of § 25.812(b)(1)(i) at amendment 25-58. An exit sign with reduced background area, as described in Special Condition 4(a), may be used to meet this requirement. e. For sections within a LD-MCR compartment that are created by the installation of a partition with a door separating the sections, the following requirements of these special conditions must be met with the door open and with the door closed:
(1)There must be a secondary evacuation route from each section to the main deck, or it must be shown that any door between the sections has been designed to preclude anyone from being trapped inside the compartment. Removal of an incapacitated crewmember from this area must be considered. A secondary evacuation route from a small room designed for only one occupant for a short period of time, such as a changing area or lavatory, is not required. However, removal of an incapacitated occupant from this area must be considered.
(2)Any door between the sections must be shown to be openable when crowded against, even when crowding occurs at each side of the door.
(3)There may be no more than one door between any seat or berth and the primary stairway exit.
(4)There must be exit signs in each section that meet the requirements of § 25.812(b)(1)(i) at amendment 25-58, that direct occupants to the primary stairway exit. An exit sign with reduced background area, as described in Special Condition 4(a), may be used to meet this requirement.
(5)Special Conditions 5 (emergency illumination), 7 (aural emergency alarm), 8 (fasten seat belt signal or return to seat signal as applicable) and 10 (smoke and fire detection) must be met both with the door open and the door closed.
(6)Special Conditions 6 (two-way voice communication) and 9 (PBE and other equipment) must be met independently for each separate section, except in lavatories or other small areas that are not intended to be occupied for extended periods of time. 15. Where a waste disposal receptacle is fitted, it must be equipped with a built-in fire extinguisher designed to discharge automatically upon occurrence of a fire in the receptacle. 16. Materials, including finishes or decorative surfaces applied to the materials, must comply with the flammability standards of § 25.853 at amendment 25-66. Mattresses must comply with the flammability standards of § 25.853(b) and
(c)at amendment 25-66. 17. A lavatory within the LD-MCR compartment must meet the same requirements as a lavatory installed on the main deck, except with regard to Special Condition 10 for smoke detection. 18. When a LD-MCR compartment is installed or enclosed as a removable module in part of a cargo compartment, or is located directly adjacent to a cargo compartment without an intervening cargo compartment wall, the following conditions apply: a. Any wall of the LD-MCR compartment, which forms part of the boundary of the reduced cargo compartment and is subject to direct flame impingement from a fire in the cargo compartment, and any interface item between the LD-MCR compartment and the airplane structure or systems must meet the applicable requirements of § 25.855 at amendment 25-60. b. Means must be provided to ensure that the fire protection level of the cargo compartment meets the applicable requirements of §§ 25.855 at amendment 25-60; 25.857 at amendment 25-60; and 25.858 at amendment 25-54 when the LD-MCR compartment is not installed. c. Use of each emergency evacuation route must not require occupants of the LD-MCR compartment to enter the cargo compartment in order to return to the passenger compartment. d. The aural emergency alarm specified in Special Condition 7 must sound in the LD-MCR compartment in the event of a fire in the cargo compartment. 19. Means must be provided to prevent access into the Class C cargo compartment, whether or not the LD-MCR compartment is installed, during all airplane flight operations, and to ensure that the maintenance door is closed and secured during all airplane flight operations. 20. All enclosed stowage compartments within the LD-MCR compartment that are not limited to stowage of emergency equipment or airplane supplied equipment ( *i.e.,* bedding), must meet the design criteria given in the table below. As indicated in the table, enclosed stowage compartments larger than 200 ft 3 in interior volume are not addressed by these Special Conditions. The in-flight accessibility of very large enclosed stowage compartments, and the subsequent impact on the crewmembers' ability to effectively reach any part of the compartment with the contents of a hand fire extinguisher will require additional fire protection considerations similar to those required for inaccessible compartments such as Class C cargo compartments. Fire protection features Stowage compartment interior volumes Less than 25 ft 3 25 ft 3 to 57 ft 3 57 ft 3 to 200 ft 3 Materials of Construction 1 Yes Yes Yes. Detectors 2 No Yes Yes. Liner 3 No No Yes. Location Detector 4 No Yes Yes. 1 *Material:* The material used to construct each enclosed stowage compartment must at least be fire resistant and must meet the flammability standards established for interior components per the requirements of § 25.853. For compartments less than 25 ft 3 in interior volume, the design must ensure the ability to contain a fire likely to occur within the compartment under normal use. 2 *Detectors:* Enclosed stowage compartments equal to or exceeding 25 ft 3 in interior volume must be provided with a smoke or fire detection system to ensure that a fire can be detected within a one-minute detection time. Flight tests must be conducted to show compliance with this requirement. Each system (or systems) must provide:
(a)A visual indication in the flight-deck within one minute after the start of a fire;
(b)An aural warning in the crew rest compartment; and
(c)A warning in the main passenger cabin. This warning must be readily detectable by a flight attendant, taking into consideration the positioning of flight attendants throughout the main passenger compartment during various phases of flight. 3 *Liner:* If it can be shown that the material used to construct the stowage compartment meets the flammability requirements of a liner for a Class B cargo compartment, no liner would be required for enclosed stowage compartments equal to or greater than 25 ft 3 but less than 57 ft 3 in interior volume. For all enclosed stowage compartments equal to or greater than 57 ft 3 but less than or equal to 200 ft 3 in interior volume, a liner must be provided that meets the requirements of § 25.855 at amendment 25-60 for a Class B cargo compartment. 4 *Location Detector:* LD-MCR compartments that contain enclosed stowage compartments with an interior volume that exceeds 25 ft 3 and are located away from one central location, such as the entry to the LD-MCR compartment or a common area within the LD-MCR compartment, would require additional fire protection features or devices to assist the firefighter in determining the location of a fire. Issued in Des Moines, Washington, on July 8, 2019. Mary A. Schooley, Acting Manager, Transport Standards Branch, Policy and Innovation Division, Aircraft Certification Service. [FR Doc. 2019-14784 Filed 7-10-19; 8:45 am]
Connectionstraces to 2
4 references not yet in our index
  • 14 CFR 25
  • 14 CFR 34
  • 14 CFR 36
  • 14 CFR 91
Citation graph
cites case law
Unknown
Final special conditions
Cite14 CFR 25
Cite14 CFR 34
Cite14 CFR 36
Cite14 CFR 91
Cites 6Cited by 0 across 0 sources
★   the supreme law of the land   ★
Don't Tread on Me
E Pluribus Unum — out of many, one

"If you don't know your rights, you don't have any."

Marginalia · a citizen's law index
A research desk, not legal advice. Always read the cited source before relying on a summary.
Questions or an issue? support@self-law.org
disclaimerMarginalia is a research index, not a law firm. Nothing on this site is legal, tax, or financial advice and no attorney–client relationship is formed by using it. Statutes, regulations, and case law change; summaries, search results, AI output, and member posts may be incomplete, out of date, or wrong. Any interpretation drawn from material on this site should be validated by a licensed attorney in your jurisdiction before you act on it.